Weather Sensors

Pizzi Instruments offers a wide range of instruments for meteorological and environmental monitoring to be integrated into geotechnical and structural monitoring systems.
The sensors are connected to our automatic acquisition units CUM3000 or DAC3000, also used for all other sensors in a system. This makes it possible to correlate structural data with environmental data, parameters for the latter often being at the origin of changes in geological and structural problems.

Contact us for further information

Edit

Applications

Each instrument has its own specific application and all instruments have the same purpose: monitoring meteorological and environmental parameters in order to predict significant changes of climate which could cause major problems for work activities, people and structures.
Typical applications for all weather instrumentation are:

  • All types of Dams
  • Rivers
  • Monuments and archaeological sites
  • Landslides
  • Galleries
  • Excavations
  • Mining
  • Other

Features and Benefits

    • Accuracy
    • Measurement speed
  • Long-term repeatability
  • Easy to use
  • Automated Measurements
  • Remote instrumentation management by dedicated control unit and software
  • Instrumentation compliant with ISO9060 standards, and IEC-17025 to WMO

Measuring Principle

Each instrument has its own mode of operation and its own measuring principle, in fact, each sensor measures a different parameter from all other sensors. Their shared purpose is monitoring such parameters in order to anticipate potential changes in weather conditions and monitor their various phases of development.
Optimum management of observations is essential, as these are the first link in the chain, both from a technical and scientific perspective. Observations form the basis for understanding phenomena and for subsequent weather forecasting.

Technical Features

BAROMETER

Instrument for measuring atmospheric pressure . Its meteorological use is for forecasting weather.

Models:

– TEM3201002 sensor with a 0-2Vdc output signal
– TEM3201001 sensor with a 4-20 mA output signal

Technical Features

Measuring Type Atmospheric Pressure
Transducer Semiconductor
Measuring Range 700 mB/1100 mB
Accuracy ± 0,5 mB
Sensitivity 0,1 mB
Output Signal 2 V (700 mB) / + 2 V (1100 mB)‏ or 4-20 mA
Working Temperature -30°C/ +70° C  Compensation in temperature
Dimensions L110xP60xH80 mm
Weight 300 g

RAIN GAUGE

Instrument for measuring rainfall with surface collection of water.

Models:

– TEM2001103 collection surface 1000cm², pulse output

Technical Features

Measuring Type Rainfall
Trasduttore Bascula oscillante
Collection Surface 400 cm2 or 1000cm2
Range 0-200 mm/h
Accuracy ± 2%
Sensitivity 0,2 mm
Signal Output Reed Contact o 4-20 mA
Working temperature -10°C/ +80° C

THERMOMETER

Instrument for measuring air and water temperatures

Models:

– Output Signal PT100
– Output Signal 0-2Vdc
– Output Signal 4-20mA

Technical Features

Measuring Type Environmental Temperature
Transducer PT100 thermoresistances or thermistor
Range -40°C/ +60°C (altri disponibili su richiesta)
Accuracy ± 0,1°C
Resolution 0,01°C
Output signal Variation of resistance or 4-20 mA o 0-2Vdc
Dimensions Diameter 240 mm and height  200 mm
Weight 1 kg

HYGROMETER

Instrument for measuring relative humidity of the air, i.e. the ratio between absolute humidity (defined as the quantity of water present in the atmosphere in a specific moment) and saturation humidity.

Models:
– Hygrometer with output 4-20 mA
– Hygrometer with forced ventilation with output 4-20 mA
– Hygrometer with output 0-1Vdc
– Hygrometer with forced ventilation 0-1Vdc

Technical Features

Measuring Type Environmental Humidity
Transducer Capacitive
Measuring Range 0-100%
Precision ± 2% F.S.
Sensitivity 0,5%
Output signal 0/1 Vcc o 4-20 mA
Dimensions Diameter 240 mm and height 200 mm
Weight 1 kg

ANEMOMETER (Wind Speed)

Instrument for measuring wind speed

Models:
– Output 4-20 mA
– Output 0-2 Vdc

Technical Features

Measuring Type Wind Direction
Transducer 3 cups with toroidal magnet and Hall effect sensor
Measuring Range 0,28 – 50 m/s
Accuracy 0,1 m/s in the range of 0,4 a 30 m/s; <± 1% over than 30 m/s
Sensitivity 0,05 m/s
Output Signal 0-2 Vcc o 4/20 mA
Working temperature -10°C +70°C
Dimensions Diameter 370 mm and height 250 mm
Weight 800 g

ANEMOMETER (Wind Direction)

Instrument for measuring wind direction

Models:
– Output signal : 0-2 Vdc
– Output signal : 4-20 mA

Technical Features

Measuring Type Wind direction
Transducer Vane with potentiometer sensor
Measuring range 0-359°
Accuracy ±  0,1°
Sensitivity 0,1°
Output Signal 0-2 Vcc o 4/20 mA
Working temperature -10°C +70°C
Dimensions Diameter 370 mm and height 430 mm
Weight 300 g

EVAPORIMETER

System for measuring water evaporation, consisting of:
– Stainless steel tank
– LVDT sensor for measuring the water level in the tank, range 0÷100mm, 0÷200mm

Technical Features

Measuring Type Water Evaporation
Transducer LVDT
Measuring Range ± 25 mm
Accuracy ± 0,5% F.S.
Sensitivity 0,1 m
Output signal 0-2 Vcc o 4/20 mA
Working temperature -2°C/+70°C
Dimensions of the stainless steel tank Diameter 120 mm

GLOBAL SOLAR RADIATION SENSOR (PYRAMOMETER)

Instrument that monitors the solar radiation for the full solar spectrum range.

Models:
 TEM6001302 oputput -5/+5 V
 TEM6001301 output 4-20 mA

Technical Features

Measuring type II Class Thermopile Pyramometer
Transducer Electronical
Measuring Range 0 ÷ 2000W/m2
Sensitivity 10µV/m2
Output Signal 0÷2Vdc, 4÷20mA, RS485/Modbus
Working Temperature -40 ÷ +80°C
Dimensions of the stainless steel tank Diameter 92 mm and height  220 mm
Power Supply 10 ÷ 30Vdc
According to Standard ISO9060, WMO e IEC-17025

Technical Assistance

If you have any requests or questions about our instruments or if you have special needs that require different solutions from the standard, please contact us. Our team will provide all the necessary information and will be very happy to work with you to study, develop and customize instruments and solutions suitable for your specific needs.

All information in our datasheet is subject to change without prior notice.
Please check the datasheet/details carefully and